Table 1 Stress and hemodynamic measurement

From: Panic attack triggering myocardial ischemia documented by myocardial perfusion imaging study. A case report

Measures Before 20 s after 1 min after 4 min after
VAS-A 5 6 6 6
PSS   Mild chest pain, palpitations and dizziness Denied panic attack  
HR (BPM) 78 89 83 74
BP (mm/Hg) 140/80 160/90 190/100 160/80
PO2 (%) 98 96 98 90
DP (bpm x mm/Hg) 10,920 14,240 15,770 11,840
  1. Abbreviations: VAS-A= Visual Analogue Scale for Anxiety; PSS=Panic Symptoms Scale; HR= Heart Rate; BP= Blood Pressure; PO2= Pulse Oximetry; DP= Double Product.